Tripp Lite 3kVA 2.7kW Smart Online UPS, Double Conversion
Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss This 200/208/220/230/240V 50/60 Hz UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in online and battery modes. Featuring a 2700W capacity, high 0.9 power factor, 570 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time to battery mode in on-line doubleconversion mode, the SmartOnline?? SUINT3000LCD2U double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment. Set Power Strategies to Reflect Your Protection Priorities Pick your power strategy, from precise power for sensitive systems to the highest possible electrical efficiency, while ensuring 100% uptime.
| UPC Code |
037332185631 |
| UPS Type |
On-Line |
OUTPUT
| Output Volt Amp Capacity (VA) |
3000 |
| Output kVA Capacity (kVA) |
3 |
| Output Watt Capacity (Watts) |
2700 |
| Output kW Capacity (kW) |
2.7 |
| Power Factor |
0.9 |
| Crest Factor |
3:1 |
| Nominal Voltage Details |
Nominal output voltage is user configured on first power-on |
| Frequency Compatibility |
50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion |
| Frequency Compatibility Details |
Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation |
| Output Voltage Regulation (Line Mode) |
+/- 2% |
| Output Voltage Regulation (Economy Line Mode) |
+/- 10% |
| Output Voltage Regulation (Battery Mode) |
+/- 2% |
| Included Output Power Cables |
Includes 2 C13 to C14 and 1 C19 to C20 power cables |
| Load Management Receptacles |
Two switchable 4 outlet load banks (3 C13 and 1 C19 per bank) |
| Output AC Waveform (AC Mode) |
Pure Sine wave |
| Output AC Waveform (Battery Mode) |
Pure Sine wave |
| Output Capacity Details |
DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 1890 watts for 208/220/230/240V output voltages; Max output is reduced to 2160W at 200V output voltage in all operating modes OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits). |
| Nominal Output Voltage(s) Supported |
200V; 208V; 220V; 230V; 240V |
| Output Receptacles |
(8) C13; (2) C19 |
| Individually Controllable Load Banks |
Yes |