Description
FINVATA1202 Single-phase INVERTER with intelligent energy storage system and UPS function rated output power 1200VA – 1200W, sinusoidal output voltage 230 Vac 50/60 Hz, MPPT voltage working range 17-80 Vdc, maximum open circuit voltage 102 Vdc, current maximum from PV 50A, battery voltage 12 Vdc, maximum battery charging current 60A, mains input 90-280 Vac 50/60 Hz, USB interface for programming and viewing operating parameters via Watchpower software, WxHxD 22.5 x32x10.3 cm, weight 4,4Kg
Technical data
| Code |
FINVATA1202 |
| Rated Power |
1.200VA / 1.200W |
| Input |
|
| Voltage |
230 VAC |
| Selectable Voltage Range |
170-280 VAC (For Personal Computers) ; 90-280 VAC (For Home Appliances) |
| Frequency Range |
50 Hz/60 Hz (Auto sensing) |
| Output |
|
| ACVoltage Regulation(Batt. Mode) |
230VAC ‡ 5% |
| Surge Power |
2.000VA |
| Efficiency (Peak) |
90% ~ 93% |
| Transfer Time |
10 ms (For Personal Computers) ; 20 ms (For Home Appliances) |
| Waveform |
Pure sinewave |
| Battery |
|
| Battery Voltage |
12 Vdc |
| Floating Charge Voltage |
13.5 Vdc |
| Overcharge Protection |
16 Vdc |
| Solar Charger & AC Charger |
|
| Solar Charger Type |
MPPT |
| Maximum PV Array Open Circuit Voltage |
102 Vdc |
| Maximum PV Array Power |
700 W |
| MPPT Range @ Operating Voltage |
17~80 Vdc |
| Maximum Solar Charge Current |
50 A |
| Maximum AC Charge Current |
20 A |
| Maximum Charge Current |
60 A |
| Physical |
|
| Dimension, D x W x H (mm) |
103x225x320 |
| Net Weight |
4.4 Kg |
| Communication Interface |
USB/RS232 |
| Environment |
|
| Humidity |
5% to 95% Relative Humidity (Non-condensing) |
| Operating Temperature |
-10°C to 50°C |
| Storage Temperature |
-15°C to 60°C |