Description
Belden GUSN806 Specifications
Environmental Space
Indoor/Outdoor – Euroclass Dca
Suitable Applications
For outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and/or tubes.
Construction
Fiber Cable Construction
- Fiber Type: OS2
- Fiber Grade acc. ITU-T: G.652D & G.657A1
- Fiber Count: 6
- Subunit Color: TIA coding (Gxxxxxx.T): Natural
Fiber Color Coding
TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White
Cable Core Water Tight
Yes
Cable Core Waterblocking
Waterblocking Glass Yarns
Bulk Cable Weight
37 kg/km
SubUnit Specifications
- Number of Active Subunits: 1
- Number of Subunit Positions: 1
- Fibers Per Subunit: 6
Jacket Specifications
- Number of Jackets: Single Jacket
- Type of Armor: Non-Armored
Outer Jacket Specifications
- Outer Jacket:
- Material: LSZH – Low Smoke Zero Halogen (Flame Retardant)
- Nominal Diameter: 5.8 mm
- Ripcord: No
Table Notes
Standard color: Orange. Available colors: Orange, Yellow, Turquoise, Erika Violet, Red, Blue, Green, Brown, Violet, Pink, Grey, White, Black, Lime Green
Optical Characteristics
- Max. Attenuation at 1310 nm: 0.39 dB/km
- Max. Attenuation at 1550 nm: 0.24 dB/km
- Max. Attenuation at 1625 nm: 0.29 dB/km
Mechanical Characteristics
Mechanical Tests
- Cable Min. Bend Radius Installation (Short Term):
- Tested Standard: IEC 60794-1-21-E6
- Requirement/Value: 116 mm
- According to Family Specification: IEC 60794-3-10
- Cable Min. Bend Radius Operation (Long Term):
- Tested Standard: IEC 60794-1-21-E11
- Requirement/Value: 58 mm
- According to Family Specification: IEC 60794-3-10
- Cable Max. Tensile Strength Installation (Short Term):
- Tested Standard: IEC 60794-1-21-E1
- Requirement/Value: 1500 N (337 lbf)
- According to Family Specification: IEC 60794-3-10
- Cable Max. Tensile Strength Operation (Long Term):
- Tested Standard: IEC 60794-1-21-E1
- Requirement/Value: 500 N (112 lbf)
- According to Family Specification: IEC 60794-3-10
- Cable Max. Crush Resistance Installation (Short Term):
- Tested Standard: IEC 60794-1-21-E3
- Requirement/Value: 15 kN/m
- According to Family Specification: IEC 60794-3-10
- Cable Max. Crush Resistance Operation (Long Term):
- Tested Standard: IEC 60794-1-21-E3
- Requirement/Value: 7.5 kN/m
- According to Family Specification: IEC 60794-3-10
Temperature Range
- Operating Temperature Range: -30 °C to +70 °C
- Installation Temperature Range: -5 °C to +50 °C
- Storage Temperature Range: -30 °C to +70 °C
Product Material
- UL Rating/Flame Test: Non-UL Rated
Standards
IEC Flammability
- IEC 60332-1-2
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity
- 10 µS/mm
IEC 60754-1 – Halogen Amount
- Zero
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH
- 4.3
IEC 61034-2 – Smoke Density Min. Transmittance
- 60%
CPR Euroclass
- Dca-s2,d1,a1
REACH
- Compliant
ISO/IEC Compliance
- IEC 60794
UV/ Sunlight Protection
- Yes
Update and Revision
- Revision Number: 0.124
- Revision Date: 12-14-2023
- Datasheet
Belden GUSN806 Part Numbers
- GUSN806.T02100: Black, Reel, 2,100 m, 8719605147950
- GUSN806.002100: Orange, Reel, 2,100 m, 8719605083487
- GUSN806.004100: Orange, Reel, 4,100 m, 8719605083494
- GUSN806.012100: Yellow, Reel, 2,100 m, 8719605083500






Reviews